Skip to content

LumaSwitch Troubleshooting

This page covers common LumaSwitch setup and power distribution issues.


Common Issues

Problem What To Check
No link lights after power-up Verify upstream fuse, polarity, and that battery voltage is present at the WAGO input.
Radio has no network through switch Confirm radio is connected to the non-PoE uplink port on the power-input side.
Device should be non-PoE but is unstable Remove the PoE fuse for that port to disable passive PoE output.
PoE device not powering Confirm the port has a properly seated fuse and the red PoE LED is lit.
Entire switch dies on single downstream short Recheck fuse coordination: downstream PoE fuses should be lower than upstream switch protection.

Next Steps